Detail Low Capacity BCL-A
* Low capacity.
Loading plate can be greater taken.
Specifications
Rated capacity 2.942 N { 300 gf} ~ 44.13 N { 4.5 kgf}
Safe overload 150 % R.C.
Ultimate overload 200 % R.C.
Rated output 1.6 mV/ V 0.2 mV/ V
Non-linearity 0.02 % R.O.
Hysteresis 0.02 % R.O.
Repeatability 0.02 % R.O.
Creep 0.02 % R.O./ 20 min
Excitation, recommended 10 V or less
Excitation, maximum 15 V
Zero balance 0.04 mV/ V
Input resistance 420
Output resistance 350 5
Insulation resistance 2 000 M or more( DC50 V)
Temp. range, compensated -10 ~ 50
Temp. range, safe -10 ~ 50
Temp. effect on zero 0.04 % R.O./ 10
Temp. effect on output 0.02 % LOAD/ 10
Cable 3.2, 4-cores shielded 40 cm cable directly attached and cable ends is separated.
Class of protection IP40
Material of element Alluminium alloy
Durability 1 000 000 times with rated load applied
Effect of eccentric load BCL-300GM, 600GM
- Size of loading plate is 200 mm x 200 mm at maximum.
- The center of loading plate and the center of load cell should be the same position
- Error is within 0.02 % R.O. applied with 1/ 2 of rated capacity at the position of 50 mm of eccentricity.
BCL-1.2K, 1.5K, 3K
- Size of loading plate is 300 mm x 300 mm at maximum.
- The center of loading plate and the center of load cell should be the same position
- Error is within 0.02 % R.O. applied with 1/ 2 of rated capacity at the position of 75 mm of eccentricity.
Kunjungi WEBSITE kami juga di : http: / / timbanganindonesia.com
Kontak Person: Andri, Ibu Sri ( 082 1147 06 170, 0819 3234 5260, 0816 1740 8891, 021-9529 3259, 0816 1740 8926 ( Sri) )
Alamat: Jl. Radin Inten II No. 62 Duren Sawit - Jakarta 13440
Telp. + 62-21 8690 6777, 8690 6771, 8690 6785
Fax : + 62-21 8690 6770
EMAIL : sales@ rajaloadcell.com
Website: www.rajaloadcell.com